STANDARDS, TESTS, AND APPROVALS
Surface Burning Characteristics (ASTM E-84): All panel components have a Flame Spread rating of less than 25.
Note: Building code requirements may necessitate composite panel testing based
on specified finish. A panel comprised of "Class A" (Flame Spread of 25 or less)
components does not necessarily produce a composite panel meeting the "Class A" requirement. Decoustics has a considerable number of composite panel tests on file.
Acoustical Data (ASTM C423, Type A Mounting per ASTM E795): Panels were tested with 3/16" (5 mm) clip mounting.

FINISH PANEL THICKNESS FREQUENCY (Hz) NRC SAA
125 250 500 1000 2000 4000
Fabric
1-1/8" (28 mm) 0.17 0.60 1.02 1.08 0.93 0.82 0.90 0.89
Fabric
1-5/8" (41 mm) 0.42 0.72 1.10 1.11 0.98 0.92 1.00 .
Fabric
2-1/8" (54 mm) 0.54 0.87 1.03 1.14 0.94 0.91 1.00 0.98
MOUNTING METHODS
Mount panels to walls using mechanical fastening, adhesive, magnetic fastening or hook and loop fastening.
Mechanically mount only for panels located above head height (includes slide and engage z-clips, wall clips and/or track).
Only handle panels wearing clean, lightweight, white gloves during installation.
If necessary, shim adhesive, magnetic and hook and loop pile mounted panels to ensure flat substrate.
Use adhesive and mechanical fastening to secure "loop" to wall i.e. stapled with splayed-outward legs.
Consult with fastener manufacturer to determine correct fastener to use for specific substrates, particularly plaster or gypsum board.
Note: It is not always possible to secure panels or mounting hardware to a substrate support such as a steel stud.
Follow manufacturer's printed instructions for installation. Field cutting of panels is not recommended.

Note: Only handle panels wearing clean, lightweight, white gloves during installation.Follow manufacturer's printed instructions for installation as well as field cutting of panels.

Note: The information provided in this Data Sheet is accurate to the best of our knowledge at the time of printing. However, we reserve the right to make changes when necessary without further notification. Suggested applications may need to be modified to conform with local building codes and conditions. We cannot accept responsibility for products that are not used, or installed, to our specifications.

...
FINISH EDGE OPTIONS PANEL SIZES
CONSTRUCTION
THICKNESS
NRC
WEIGHT

Fabric
Resin: square only.
Fabric only: Up to 60" x 120" (1525 mm x 3050 mm).

Finish width must be sufficient to cover panel, panel thickness, and wrap minimum 1" (25 mm) on back side.
Stria panel is an inert, dimensionally stable, panel consisting of a 6 to 7 pcf (96 to 112 kg/m3) medium density core with a 1/8" (3 mm) thickness 16 to 20 pcf (256 to 320 kg/m3) high density acoustically transparent integral facer, and fabric finish. Fabric corners are fully tailored (no exposed darting).
1-1/8"
(28 mm)

1-5/8"
(41 mm)

2-1/8"
(54 mm)
0.90


1.00


1.00
1.2 psf
(5.86 kg/m2)

1.45 psf
(7.10 kg/m2)

1.75 psf
(8.55 kg/m2)